Configuring Brother C00 CNC Machines for Efficient Monitoring

Add machine - Brother C00 CNC Monitoring Configuration

How to add machine - Brother C00 CNC Monitoring Configuration

Applicable to the C Series.

FactoryWiz Settings
  1. Login as an Admin
  2. Navigate to CONFIGURATION > MACHINE
  3. ADD
  4. Input the name of the machine 
  5. Set the machine type to Brother
  6. Set the IP address, Brother Type and Port Number (set below, normally 10000)
  7. Save.
  8. Navigate to CONFIGURATION > LICENSING
  9. Increase the Brother license allocation accordingly and save

CNC Settings

To access the Ethernet settings page, put the machine into EDIT mode.

Press: DATA BANK > 6. Communication Parameters > Ethernet / FTP

Reset Slave = 1
Data Overwrite = 1
Remote Operation = 1
Display Slave Alarm = 0
Use DHCP = 0
IP Address = Set the ip here *
Subnet = Your subnet *
Gateway = Set if required *
Port No = 10000
Restrict Ethernet Access = 0 (not on all controls)

Press Completion Mode > Exit w/change to save the changes. 
Restart the control.

* When you enter an IP address you do not enter the point and you must enter leading zeros, for example:

192.168.0.50 IP address is entered as 192168000050

These settings can also be set for customers using FactoryWiz MTConnect on a Brother control.


    • Related Articles

    • Add Machine - Haas NGC Configuration for FactoryWiz

      Haas NGC Configuration for FactoryWiz On the Haas CNC 1. Press Setting and move the tab to wired connection. Here you must set the machine IP and Subnet 2. Next go to SETTINGS tab and search for setting 143. Set 8000 to use TCP port 8000 for ...
    • Add machine - Siemens OPC-UA (v4.05) Monitoring Configuration

      Adding Siemens OPC-UA (v4.05) for monitoring Pre checks 1. Check the machine has the required software version 4.05 [MENU SELECT] > {diagnostics} > {version}. 2. Check if the Access My Machine option is on (if it is not on then we can turn it on ...
    • Add Machine - Kitamura Anywhere remote for FactoryWiz Monitoring

      Configure Kitamura Anywhere remote for FactoryWiz Monitoring Note: This document does not apply to Junior control. In FactoryWiz Login as an Admin Navigate to CONFIGURATION > MACHINE ADD Input the name of the machine (make an EXACT note of this name) ...
    • Preparing for FactoryWiz Monitoring

      Preparing for FactoryWiz Monitoring FactoryWiz Installation This document is to help you understand the preparation which is required to ensure that your system deployment goes as smoothly as possible. We want to make sure that you have a good ...
    • 8.7.6 Add A New Machine

      To add a new machine to FactoryWiz™ Monitoring, click the Add New Machine button in the Select Machine pane in the top left corner of the window. You will then see the Add Machine pop-up window. Enter a unique name for the new machine. If the new ...