Add machine - Brother C00 CNC Monitoring Configuration
Applicable to the C Series.
FactoryWiz Settings
- Login as an Admin
- Navigate to CONFIGURATION > MACHINE
- ADD
- Input the name of the machine
- Set the machine type to Brother
- Set the IP address, Brother Type and Port Number (set below, normally 10000)
- Save.
- Navigate to CONFIGURATION > LICENSING
- Increase the Brother license allocation accordingly and save
CNC Settings
To access the Ethernet settings page, put the machine into EDIT mode.
Press: DATA BANK > 6. Communication Parameters > Ethernet / FTP
Reset Slave = 1
Data Overwrite = 1
Remote Operation = 1
Display Slave Alarm = 0
Use DHCP = 0
IP Address = Set the ip here *
Subnet = Your subnet *
Gateway = Set if required *
Port No = 10000
Restrict Ethernet Access = 0 (not on all controls)
Press Completion Mode > Exit w/change to save the changes.
Restart the control.
* When you enter an IP address you do not enter the point and you must enter leading zeros, for example:
192.168.0.50 IP address
is entered as
192168000050

These settings also be set for customers using FactoryWiz MTConnect on a Brother control.
Related Articles
Add Machine - Mazak Monitoring
PDF with pictures attached below. In FactoryWiz: Login as an Admin Navigate to CONFIGURATION > MACHINE ADD Input the name of the machine Set the machine type to Mazak Set IP address Save. Navigate to CONFIGURATION > LICENSING Increase the Mazak ...
Add machine - Okuma Thinc Monitoring Configuration
The Okuma thinc api and thinc startup service must be installed prior to installing FactoryWiz onto the Okuma CNC. Getting the right files We need to know the api version for each Okuma you have so we can send you the correct installation files: ...
Add Machine - Fanuc Focas Monitoring Configuration (embedded ethernet)
This guide is for the embedded ethernet (CD38A) not Data Server or Fast Board. In FactoryWiz: Login as an Admin Navigate to CONFIGURATION > MACHINE ADD Input the name of the machine Set the machine type to Fanuc Focas Add the IP address and port to ...
Add Machine - Haas NGC Configuration for FactoryWiz
Haas NGC Configuration for FactoryWiz On the Haas CNC: 1. Press Setting and move the tab to wired connection. Here you must set the machine IP and Subnet 2. Next go to SETTINGS tab and search for setting 143. Set 8000 to use TCP port 8000 ...
Add Machine - Kitamura Anywhere remote for FactoryWiz Monitoring
Configure Kitamura Anywhere remote for FactoryWiz Monitoring Note. This document does not apply to Junior control. In FactoryWiz: Login as an Admin Navigate to CONFIGURATION > MACHINE ADD Input the name of the machine (make an EXACT note of this ...