CNC Configuration Sheet
Cincinnati 2100
CNC Parameters:
You will need to verify all parameters listed below
that correspond to your CNC control.
These parameters may not match your particular machine’s control.
Baud Rate: 9600
FactoryWiz DNC Settings:
Basic Communication
1.01- Port Type: StandardSending Options
2.11- Leader: Leave blank
2.12- Trailer: Leave blank
2.23- Skip lines that contain: Leave blank
2.31- Automatic timeout: 7
Receiving Options
3.11- Program identifier 1: (
3.12- Program Identifier 2:
3.21- Receive timeout: 3
3.31- Ignore data before first end-of-block: False
3.32- Ignore data after last end-of-block: False
Remote Commands
4.02- Request for file command: GET-
4.03- Request for file command (drip feed):
4:11- Request to save command:
Additional Notes:
Changing CNC Parameters:
To set up parameters:
Click on MORE
Click on SYSTEM CONFIGURATION
Click on CNC COM SETUP
Click on HARDWARE tab
Change parameters as needed.
Outputting CNC Programs:
Click on HOME SCREEN
Click on PROGRAMS
Click on TRANSFER PROGRAM
Cursor to program that will be sent
Click on OUTPUT
Click on COM PORT
Click on START TRANSFER
Inputting CNC Programs:
Click on HOME SCREEN
Click on PROGRAMS
Click on TRANSFER PROGRAM
Click on INPUT
Click on COM PORT
Click on START TRANSFER
Wiring Diagram:
Pinout includes RTS/CTS Handshaking DB9 at machine
DB-9 com port |
Wire color |
DB-9 CNC |
Jumper? |
|
|
(Disconnected) |
Shield |
1 |
|
|
2 (Receive Data) |
Green |
3 (Transmit Data) |
|
|
3 (Transmit Data) |
Red |
2 (Receive Data) |
|
|
5 (Signal Ground) |
Black |
5 (Signal Ground) |
|
|
7 (RTS) |
Brown |
8 (CTS) |
|
|
8 (CTS) |
Blue |
7 (RTS) |
|
|
|
|
6 (DSR) 1 (DCD) 4 (DTR) |
JUMPER |
Pinout includes RTS/CTS Handshaking DB25 at machine
DB-9 com port |
Wire color |
DB-25 CNC |
Jumper? |
|
|
(Disconnected) |
Shield |
1 |
|
|
2 (Receive Data) |
Green |
2 (Transmit Data) |
|
|
3 (Transmit Data) |
Red |
3 (Receive Data) |
|
|
5 (Signal Ground) |
Black |
7 (Signal Ground) |
|
|
7 (RTS) |
Brown |
5 (CTS) |
|
|
8 (CTS) |
Blue |
4 (RTS) |
|
|
|
|
6 (DSR) 8 (DCD) 20 (DTR) |
JUMPER |