Haas Ethernet - UNC-Intermetiate Configuration Sheet

Haas Ethernet - UNC-Intermetiate Configuration Sheet

stems CNC Configuration Sheet


Haas Ethernet – UNC_Intermediate


CNC Parameters: 

You will need to verify all parameters listed below that correspond to your CNC control. These parameters may not match your particular machine’s control. Document (Phone camera) original settings before making modifications! 


On Haas Control

Press Settings. 

Cursor to top of screen then navigate to Network settings. 

Select Wired Connection. 

Wired Network Enabled: ON, then press ENTER. 

Obtain Address Automatically: OFF, then press ENTER. 

IP Address: Enter in IP Address, then press ENTER. 

Subnet Mask: Enter in Subnet Mask, then press ENTER. 

Default Gateway: Enter Gateway, then press ENTER. 

DNC Server: do not enter anything. 

Press F4 to save changes. 

Network Status should display UP if machine is connected to an active network. 

Cursor to Network Share Information. 

CNC Network Name: Hard coded, no changes allowed. 

Domain Workgroup name: do not enter anything. 

Remote Net Share Enabled: OFF, do not change. 

Remote Server Name: do not enter anything. 

Remote User name: do not enter anything. 

Remote Password: do not enter anything. 

Local Net Share Enabled: ON, then press ENTER. 

Local Net Share Security: ON, then press ENTER. 

Local User Name: hard coded, cannot change (haas). 

Local Password: HAAS, press ENTER. 

Press F4 to save changes. 


FactoryWiz DNC Settings: 

Basic Communication 

1.01- Port Type: UNC_Intermediate 

1.03- UNC Path to Device: \\192.168.10.97\User data (**This is the shared folder on the Haas control**) 

1.21- End of block (EOB): LF 


Sending Options 

2.01- Send Directories: Folders to be searched (allowed) when queuing or requesting files. 

2.02- Search Subdirectories: True/False choice 

2.03- Send Extensions: File extensions that should be displayed / searched when adding files to queue

2.71- UNC target folder flush interval: 1 (value in hours) 






Receiving Options 

3.01- Receive Directories: Folder where received files from this machine will be stored. 

3.16- Auto rename type: when receiving file that exists already, overwrite, rename to .bak, or employ version numbering. 


Remote Commands 

4.02- Request for file command: GET- 

4.04- Prefix to assume for requested files: Prefix will be appended to the beginning of the file name for all requested files. 

4.05- Suffix to assume for requested files: Suffix will be appended to the end of the file name for all requested files. 

4.33- Remote request file path/name: Filename used to perform file request when placed in UNC_Intermediate folder. 


Initializenet.bat sample for Haas control (this resides in FactoryWiz DNC Server folder, and password must match the local password from above steps) 

Initializenet.bat: 

net use "\\192.168.1.40\User Data" /USER:haas HAAS 

exit 


Additional Notes: 


Outputting CNC Programs: 

At the Haas control: 

Press LIST PROG. 

Cursor down to file. 

Press F2 to copy file. 

Verify User Data is highlighted, press ENTER 

Press ENTER again. 

File will be copied to User Data folder. Once there, FactoryWiz DNC will move file from the User Data folder to the Receive folder configured for the Haas machine. 


Inputting CNC Programs: 

Queue file to be sent at FactoryWiz Clint workstation. 

File will be copied to the User Data folder on the Haas control. 

At the Haas control: 

Press LIST PROG. 

Cursor up and over to User Data field. 

Cursor down to file. 

Press F2 to copy file. 

Verify Memory is highlighted, press ENTER 

Press ENTER again.




    • Related Articles

    • Haas Ethernet - UNC Intermediate Local Share configuration document

      CNC Configuration Sheet Haas Ethernet – UNC_Intermediate Local Share  CNC Parameters: You will need to verify all parameters listed below that correspond to your CNC control.  These parameters may not match your particular machine’s control. ...
    • Haas Configuration Document

        DC Systems | Haas Confguration Settings CNC Configuration Sheet CNC Parameters: Newer Haas: Press SETNG to bring up the machine settings. Press right arrow until you get to I/O tab. Press WRITE/ENTER button (lower right corner of panel). Use left ...
    • Okuma P100 P200 P300 UNC configuration

      Okuma Configuration: On the Okuma, pressing Control plus Reset (looks like /// on the key) should bring up the start menu for Windows. In the start menu you want to run, then enter "compmgmt.msc" and click ok.   There should be a local users and ...
    • Troubleshooting Haas MDC (serial) machines

      Data collection for Haas MDC is performed in the DNC module. Haas CNC setting 143 must be enabled. Open the DNC Client Login as the admin Select the machine in question. Check the activity log for connection of license errors (if you see lacking ...
    • Add Machine - Haas NGC Configuration for FactoryWiz

      Haas NGC Configuration for FactoryWiz   On the Haas CNC: 1.     Press Setting and move the tab to wired connection. Here you must set the machine IP and Subnet 2.     Next go to SETTINGS tab and search for setting 143. Set 8000 to use TCP port 8000 ...