Configuring DPRNT on Hurco CNC Machines

Hurco DPRNT Set Up

How to set up Hurco DPRNT

1.     From menu button on left select "run program"

2.     Will be prompted for a password. Try these:

a.     46268

b.     86264

c.     8626486264

3.     Run command prompt

4.     Create C:\RYM folder

5.     Copy net dprnt files to C:\RYM folder

6.     Open CMD Line

7.     Type in the following and hit enter: C:\windows\microsoft.net\framework\v2.4.26707\installutil.exe "C:\RYM\DPRNTTransmitService.exe"

8.     Configure fwconfig.txt file

a.     Line 1: CNC name

b.     Line 2: path to DPRNT file, (D:\hurco\winmax\outputfiles\ncprint.txt)

c.     Line 3: path to SOAP api, including http://ipaddress/interface/v3/dataaccess.asmx (example http://10.1.0.50/interface/v3/dataaccess.asmx

9.     NC param - press AUX MENU button

10.  Utility screen

11.  User preferences

12.  NC settings

13.  Bprnt/dprnt output device = file

14.  Bprnt/dprnt output file (default D:\hurco\winmax\outputfiles\ncprint.txt)

15.  Restart CNC

16.  Add DPRNT commands to the NC program. Prefixs in the user manual.


    • Related Articles

    • 10.1 DPRNT Command List

      If you DPRNT information to a service for the Okuma, Hurco or Mazak (not to the FactoryWiz DNC Server), here are a list of the commands. DPRNT Command Purpose Example START Set machine status as running START FINISH Set machine as idle and increment ...
    • Haas NGC DPRNT

      HAAS DPRNT Configuration How to setup Haas NGC DPRNT to work with FactoryWiz In order to DPRNT data to FactoryWiz from a Haas NGC there are a things to set in both the CNC settings and FactoryWiz settings. Before you input any settings, you must ...
    • RYM DPRNT Transmitter Service

      How to send DPRNT commands to FactoryWiz This is a windows server that sends received DPRNT commands to FactoryWiz. This service is installed on a windows service. .Net Framework 2.0 is required. Installing the DPRNT Service 1. Create a folder in the ...
    • Mazak RYM DPRNT Transmitter Service

      .Net Framework 2.0 is required. Mazak RYM DPRNT Transmitter Service This is a windows server that sends received DPRNT commands from the Mazak CNC to FactoryWiz. This service is installed on a windows service. Installing the DPRNT Service 1. Create a ...
    • Troubleshooting Haas NGC Connection and DPRNT Test

      This guide assumes you have setup the CNC settings and FactoryWiz in this KB Article. Ping Test We use a ping test to see if the server can see the Haas machine with its given IP address. In this example, our Haas has an IP of 192.168.0.19. See how ...